GROUND HEATER E1250

There are a number of variables with ground heaters, please call with questions.

  • Thaw ground – quickly, easily, and economically up to 1,650 sq. ft.
  • Cure concrete – in cold weather with confidence up to 2,200 sq. ft. with standard equipment
  • Up to 72 hours run time 24/7.
  • Fuel-line heater for trouble-free start
  • Easy to operate hydronic heater
  • Economical
  • Dependable
  • Built tough

E1250 Technical Specifications

Dimensions

L x W x H 140 x 76 x 72 in
Operating weight 3,775 lb
Shipping weight w/trailer (no fuel) 3,330 lb
Heat transfer fluid Capacity 54 US gal
Hose length 1250 ft
Quantity Hose reels 1
Quantity Circulation Loops 1
Temperature monitor Digital

Operating data

Flow velocity Heat transfer 265 US gal/h
Hose pressure Normal Operating 110 psi
Heating power Gross input 140,000 BTU/h
Heat efficiency 87 %
Operating temperature 200 ° F
Capacity Thaw (std) 2,500 ft²
Capacity Thaw (w/acc) 3,750 ft²
Capacity Cure (std) 2,500 ft²
Capacity Cure (w/acc) 7,500 ft²
Capacity Frost prevention (std) 3,750 ft²
Capacity Frost prevention (w/acc) 11,250 ft²
Capacity Air heat capacity (w/acc) 203,600 ft³
Current 15 A
Rated voltage AC Voltage 120 V
Engine / Motor manufacturer Kubota Z602
Engine / Motor type 2-cylinder Liquid-cooled
Displacement 36.55 in³
Engine performance 16.8 hp
Engine RPM 1800 rpm
Fuel type #2 winter blend diesel
Fuel consumption Diesel 1.18 US gal/h
Tank capacity Useable 68 US gal
Runtime at 100% 68 h
Runtime at 75% 90 h